Off-line setup corrections only marginally reduce the number of on-line corrections for prostate radiotherapy using implanted gold markers.

Loading...
Thumbnail Image

Files

Access status: Embargo until 2233-03-22 , Primary 81474.pdf (252.16 KB)

Date

Authors

Vight, L.P. van der
Lin, E.N.J.T. Emile
Spitters-Post, I.
Visser, A.G. Andries
Louwe, R.J.W. Rob

Journal Title

Journal ISSN

Volume Title

Publisher

Research Projects

Organizational Units

Journal Issue

Abstract

PURPOSE: To evaluate the efficiency of combining on-line and off-line corrections for the positioning of patients receiving external beam radiotherapy for prostate cancer. MATERIALS AND METHODS: Daily portal images were acquired during the treatment of 102 patients to verify and correct the position of the prostatic gland using implanted gold markers. In addition to an existing off-line procedure, on-line corrections were applied in the anterior-posterior (AP) direction only, to limit the increase in daily workload. The possible increase in workload of the combined correction procedure for on-line corrections in either two or three directions was further investigated by simulating the required position corrections for 500 treatments. RESULTS: The combined correction procedure in AP-direction resulted in a systematic dispersion and random variation of 0.3mm (1 SD) and 1.0mm (1 SD), respectively. Application of off-line corrections during pre-treatment setup reduced the number of required on-line corrections from 22+/-4 (1 SD) to 17+/-4 (1 SD), at the cost of 1.4+/-1.0 (1 SD) off-line corrections. For on-line corrections in two or three directions, application of a combined on-line/off-line procedure did not noticeably reduce the number of setup corrections. CONCLUSIONS: The on-line procedure is feasible and significantly improves both systematic and random errors to below 1 mm with a limited impact on the workload and treatment time. The application of off-line setup corrections during pre-treatment patient positioning only marginally reduces the number of on-line setup corrections.

Description

Keywords

Citation

Endorsement

Review

Supplemented By

Referenced By