Ellipsoid zone reflectivity as a functional imaging biomarker for age-related macular degeneration: a MACUSTAR study report
Loading...
Date
Authors
Liermann, Y.N.
Behning, C.
Isselmann, B.
Schmid, M.
Dunbar, H.M.P.
Luhmann, U.F.O.
Finger, R.P.
Schmitz-Valckenberg, S.
Holz, F.G.
Pfau, M.
Journal Title
Journal ISSN
Volume Title
Publisher
Abstract
This study evaluated the functional relevance of relative ellipsoid zone reflectivity (rEZR) on spectral-domain optical coherence tomography as a structural biomarker for retinal integrity, focusing on its association with retinal function. Participants with age-related macular degeneration (AMD) and controls from the MACUSTAR study underwent functional testing, including mesopic fundus-controlled perimetry, best-corrected visual acuity, low-luminance visual acuity, low-luminance deficit, Moorfields Acuity Test, and Pelli-Robson contrast sensitivity, along with spectral-domain optical coherence tomography imaging. Structural and functional data were analyzed globally and spatially aligned for topographic analysis. Linear-mixed effects models, adjusted for age, sex, and eccentricity of the rEZR, assessed associations between rEZR and functional metrics. A total of 275 eyes (early AMD, n = 34; intermediate AMD, n = 152; late AMD, n = 36; controls, n = 53) from 275 participants (mean +/- standard deviation age: 71.1 +/- 7.2 years; 63.3% female) were included. In global analyses, rEZR was associated with the mean average threshold in mesopic fundus-controlled perimetry (coefficient estimate 0.0492, 95% confidence interval 0.0190-0.0794, p = 0.0015), low-luminance visual acuity (coefficient estimate - 0.0015, 95% confidence interval - 0.0026 to - 0.0004, p = 0.0092), Moorfields Acuity Test (coefficient estimate 0.0092, 95% confidence interval - 0.0022 to - 0.0001, p = 0.0285), and Pelli-Robson contrast sensitivity (coefficient estimate 0.0030, 95% confidence interval 0.0015-0.0045, p = 0.0001). Topographic analysis further revealed an association of rEZR with mesopic retinal sensitivity (coefficient estimate 0.0065, 95% confidence interval 0.0026-0.0104, p < 0.0001). Higher outer retinal reflectivity is linked to better retinal function in AMD and controls, supporting its potential as a biomarker for retinal integrity and function.